SCS System Comparison

Powered by SmoothWaveTM Technology, the Precision PlusTM System offers features and benefits unrivaled by other systems.

These market-leading features – designed to provide real benefits for patients and physicians – highlight a fundamental element of our design philosophy: a product designed to fit the patient.

Precision PlusTM Exclusive Features
Overview
System Type
Constant Current AT EACH CONTACT (MICC)
Constant Voltage (Single Source)
Constant Current (Single Source)
# of power sources
16
1
1
Precisely Target Pain
Move electric field in 1% increments
Yes
No
No
Tightly spaced contacts
Yes (1mm)
Yes (1.5mm)
Noa
Joystick control
Yes
No
No
Maintain Therapy
Auto impedance adjust at each contact
Yes
No
No
Multilumen lead construction
Yes
No
No
Ability to detect relative lead position
Yes (EGL ScanTM Technology)
No
No
Max pulse width
1000 µsb
1000 µsc
500 µsa
Max voltage
15 Vb
10.5 Vc
12 V a
Max frequency
1200 Hzb
1200 Hzc
1200 Hza
Fit Patient Lifestyle
Cordless charger
Yesb
Nod
Noe
Cordless remote w/24" wireless range
Yesb
Nof
Noe
Battery warranty voided by over-discharge
Nob
Yesg
Yesh
Battery explant due to over-discharge
Nob
Yesi
Yesh
End-of-life battery shutoff
No
Yes (nine years)j
No
% warranty coverage of battery life claim
100% (five-year warranty backing five-year battery life claim. Warranty not voided by over-dischargeb)
56% (five-year warranty backing nine-year battery life claim.j Warranty voided by over-discharge.g)
10% (one-year warranty backing ten-year battery life claim.h Warranty voided by over-discharge.h
Battery with contoured oval shape
Yes
No
No
IPG footprint
20cm2 k
26cm2 k
21cm2 k
Volume
22ccb
22ccc
18cca
Thickness (maximum)
11mm (battery)b
11mm (connector)l
11mm (connector)a


References

a) St. Jude Eon MiniTM Neurostimulation System Clinician’s Manual, 37-1004-01E Mar 08, p 96-107.
b) Boston Scientific Physician Implant Manual, 9055521-003 Rev A.
c) Medtronic System Eligibility Battery Longevity Specifications, MA00152A037, 2007, p 45-6.
d) Medtronic Patient Programmer Manual, 37743, 2007-09, p 43.
e) St. Jude Eon MiniTM Neurostimulation System Clinician’s Manual, 37-1004-01E Mar 08, p 17-18.
f) Medtronic Patient Programmer Manual, 37743, 2007-09, p 56.
g) Medtronic Limited Warranty, Special Notice.
h) St. Jude Eon MiniTM Neurostimulation System Clinician’s Manual, 37-1004-01E Mar 08, p 79-80, 89-90.
i) Medtronic RestoreULTRATM Implant Manual, 37712 2007-9, p 9.
j) Medtronic System Eligibility Battery Longevity Specifications, MA00152A037, 2007, p 14.
k) Boston Scientific calculations. Data on file.
l) Medtronic RestoreULTRATM Implant Manual, 37712 2007-9 p 7.